Utility of Caronia Glaucoma Card vs Amsler Grid for Monitoring Patients With Advanced Glaucoma
abstract
This abstract is available on the publisher's site.
Access this abstract nowPRÉCIS
Caronia Glaucoma Card (CGC) design incorporates a vertical and horizontal line and seven concentric circles corresponding to 1 o arc at normal reading distance. The study showed that the CGC is preferred by study patients compared to Amsler Grid and can detect central scotomas.
PURPOSE
Evaluate patient acceptance and efficacy of the Caronia Glaucoma Card (CGC) in monitoring patients with severe glaucoma.
METHODS
A retrospective study of consecutive patients with severe glaucoma who agreed to monitor their visual function. Patients were given a two-sided sheet of paper. An Amsler grid was printed on one side, and a CGC was printed on the other side. The patient was given verbal and written instructions on how to perform each test. They were asked to use either one or both tests to monitor their visual function on a weekly basis. Upon return, they were asked which test they preferred and if they appreciated or noticed any change in their scotoma. Patient comments were recorded.
RESULTS
Sixty-seven patients were given the test card whose reported past ocular history consisted solely of severe glaucoma. Seventeen patients were eventually excluded. Fourteen patients had 1 eye that fulfilled the inclusion criteria for the study, while the other eye was excluded. Eighty-six eyes of fifty patients satisfied the inclusion criteria and were enrolled in the study. Thirty of the patients were male (60%) and 20 were female (40%). The average age was 71.8 +/- 10.7 years. They all carried a diagnosis of severe glaucoma. When asked the question which test design they preferred to use, 30 patients preferred the CGC (60%), while 8 patients preferred the Amsler grid (16%). Twelve patients found no difference between the 2 test designs (24%). [χ 2 (2, 50)=16.480, ρ=0.000]. Five patients noticed a change in their scotoma while using the card (5.8%, 5 of 86 eyes). All were exclusively using the CGC.
CONCLUSION
The CGC is a convenient and inexpensive tool that was able to detect a change in scotoma. It may be helpful to add to the armamentarium to monitor glaucoma and its possible progression in patients with advanced disease.
Click on any of these tags to subscribe to Topic Alerts. Once subscribed, you can get a single, daily email any time PracticeUpdate publishes content on the topics that interest you.
Visit your Preferences and Settings section to Manage All Topic Alerts
Additional Info
Caronia Glaucoma Card Versus Amsler Grid for Monitoring Patients With Advanced Glaucoma
J. Glaucoma 2024 Apr 01;33(4)277-287, Caronia RMFrom MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.